Nitrile Examination Gloves

  • Nitrile gloves are made from acrylonitrile-butadiene rubber. This synthetic rubber has higher puncture resistance than latex gloves, as well as greater tactile sensitivity.
  • Nitrile gloves were created to address common issues with natural rubber latex gloves, such as allergic reactions and a lack of solvent protection.
  • Nitrile gloves are used in a variety of settings, including industrial, residential and healthcare. They are popular with healthcare professionals, dentists, estheticians, laboratory workers, food and chemical handlers, and workers performing general industrial duties.

Description

PRODUCT SPECIFICATION

Nitrile Powder Free Examination Gloves Palm Textured
SECTION I : PRODUCT DESCRIPTION
1. 1 Type Nitrile Examination Glove, Powder Free, Online Single Chlorinated, Non sterile
1. 2 Material 100% Synthetic Nitrile Latex
1. 3 Colour Blue
1. 4 Design & Features Ambidextrous, palm textured, beaded cuff
1. 5 Powder No powder lubricant added
1. 6 Storage Condition The gloves shall maintain their properties when stored in a dry condition. Avoid direct sunlight
1.7 Shelf Life The gloves shall have shelf life of 5 years from the date of manufacture with the above storage condition
1. 8 Packing Style 100 pcs gloves x 10 dispensers x 1 carton
1. 9 Size Marking The size of gloves shall be marked in the check box on every carton with black ink
SECTION II: PERFORMANCE REQUIREMENTS | Sampling Plan : ISO 2859 Single Normal
# Characteristics Inspection Level Acceptable Quality Level Reference Standard
2.1 Dimensions S2 4.0 ASTM D6319-19
2.2 Physical Properties S2 4.0 ASTM D6319-19
2.3 Freedom from Holes Air Pump Test GI 1.5 In house practice
2.4
i
ii
Visual Defects:
Major Visual
Minor Visual
GI 2.5
4.0
In house practice
2.5
i
ii
iii
Packaging Defects:
Regulatory
Visual Critical incl.
Gloves Counting
GI
GI
S2
**
4.0
4.0
In house practice
2.6 Powder Free Residue N=5 N/A ASTM D6319-19 ASTM D6124-06 (2017)
2.7 Mix Size / Mix Glove / Mix Hand Not Allowed

**Unacceptable at any level

SECTION III: PERFORMANCE SPECIFICATION
Dimensions
Description Size Standard
Length, mm All Sizes 300 +/- 10
Palm Width, mm XS
S
M L
XL
76 +/- 3
84 +/- 3
94 +/- 3
105 +/- 3
113 +/- 3
Thickness, mm *single wall All Sizes Finger : 0.14 +/- 0.02
Typical value: 0.13 to 0.15
Palm : 0.10 +/- 0.02
Typical value: 0.10 to 0.11

Physical Properties

Description Standard
Before Aging After Aging
Elongation at Break, % Min 500
Typical value: 500 to 600
Min 400
Typical value: 400 to 500
Tensile Strength, MPa Min 14
Typical value: 14 to 18
Min 14
Typical value: 14 to 18
3.3 Freedom from Holes: The sample size and allowable number of non conforming gloves in the samples shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements
3.4 Visual Defects: The sample size and allowable number of non conforming gloves in the samples for both major and minor defects shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements.
3.5 Packaging Defects: The Sample size and allowable number of non conforming in the samples for regulatory, visual and critical packaging defects shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements, Gloves Counting=100 pcs by count per Dispenser.
3.6 Powder Free Residue: Maximum 2 mg per glove

PRODUCT SPECIFICATION

Nitrile Powder Free Examination Gloves Finger Textured
SECTION I : PRODUCT DESCRIPTION
1. 1 Type Nitrile Examination Glove, Powder Free, Online Single Chlorinated, Non sterile
1. 2 Material 100% Synthetic Nitrile Latex
1. 3 Colour Blue
1. 4 Design & Features Ambidextrous, finger textured, beaded cuff
1. 5 Powder No powder lubricant added
1. 6 Storage Condition The gloves shall maintain their properties when stored in a dry condition. Avoid direct sunlight.
1.7 Shelf Life The gloves shall have shelf life of 5 years from the date of manufacture with the above storage condition
1. 8 Packing Style 100 pcs gloves x 10 dispensers x 1 carton
1. 9 Size Marking The size of gloves shall be marked in the check box on every carton with black ink
SECTION II: PERFORMANCE REQUIREMENTS | Sampling Plan : ISO 2859 Single Normal
# Characteristics Inspection Level Acceptable Quality Level Reference Standard
2.1 Dimensions S2 4.0 ISO 11193-1:2020
2.2 Physical Properties S2 4.0 ISO 11193-1:2020
2.3 Freedom from Holes Water Tight Test GI 1.5 ISO 11193-1:2020
2.4
i
ii
Visual Defects:
Major Visual
Minor Visual
GI 2.5
4.0
In house practice
2.5
i
ii
iii
Packaging Defects:

Regulatory
Visual
Critical incl.Gloves Counting

GI
GI
S2
**
4.0
4.0
In house practice
2.6 Powder Free Residue N=5 N/A ASTM D6319-19
ASTM D6124-06 (2017)
2.7 Mix Size / Mix Glove / Mix Hand Not Allowed

**Unacceptable at any level

SECTION III: PERFORMANCE SPECIFICATION
Dimensions
Description Size Standard
Length, mm All Sizes 300 +/- 10
Palm Width, mm XS
S
M L
XL
76 +/- 3
84 +/- 3
94 +/- 3
105 +/- 3
113 +/- 3
Thickness, mm *single wall All Sizes Finger : 0.13 +/- 0.02
Typical value: 0.11 to 0.12
Palm : 0.10 +/- 0.02
Typical value: 0.08 to 0.09

Physical Properties

Description Standard
Before Aging After Aging
Force at Break , N Min 7
Typical value: 7 to 11
Min 6
Typical value: 7 to 10
Elongation , % Min 500
Typical value: 500 to 700
Min 400
Typical value: 400 to 600
3.3 Freedom from Holes: The sample size and allowable number of non conforming gloves in the samples shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements.
3.4 Visual Defects:The sample size and allowable number of non conforming gloves in the samples for both major and minor defects shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements.
3.5 Packaging Defects: The Sample size and allowable number of non conforming in the samples for regulatory, visual and critical packaging defects shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements Gloves Counting=100 pcs by count per Dispenser.
3.6 Powder Free Residue: Maximum 2 mg per glove

PRODUCT SPECIFICATION

Nitrile Powder Free Examination Gloves Palm Textured (short cuff)
SECTION I : PRODUCT DESCRIPTION
1. 1 Type Nitrile Examination Glove, Powder Free, Online Single Chlorinated, Non sterile
1. 2 Material 100% Synthetic Nitrile Latex
1. 3 Colour Blue
1. 4 Design & Features Ambidextrous, palm textured, beaded cuff
1. 5 Powder No powder lubricant added
1. 6 Storage Condition The gloves shall maintain their properties when stored in a dry condition. Avoid direct sunlight.
1.7 Shelf Life The gloves shall have shelf life of 5 years from the date of manufacture with the above storage condition.
1. 8 Packing Style 100 pcs gloves x 10 dispensers x 1 carton
1. 9 Size Marking The size of gloves shall be marked in the check box on every carton with black ink.
SECTION II: PERFORMANCE REQUIREMENTS | Sampling Plan : ISO 2859 Single Normal
# Characteristics Inspection Level Acceptable Quality Level Reference Standard
2.1 Dimensions S2 4.0 ASTM D6319-19
2.2 Physical Properties S2 4.0 ASTM D6319-19
2.3 Freedom from Holes Air Pump Test GI 1.5 In house practice
2.4
iii
Visual Defects:
Major Visual
Minor Visual
GI 2.5
4.0
In house practice
2.5
iii
iii
Packaging Defects:
RegulatoryVisualCritical incl. Gloves Counting
GI
GIS2
**

4.0
4.0

In house practice
2.6 Powder Free Residue N=5 N/A ASTM D6319-19
ASTM D6124-06 (2017)
2.7 Mix Size / Mix Glove / Mix Hand Not Allowed

**Unacceptable at any level

SECTION III: PERFORMANCE SPECIFICATION
Dimensions
Description Size Standard
Length, mm All Sizes 300 +/- 10
Palm Width, mm XS

S

M L
XL

76 +/- 3
84 +/- 394 +/- 3
105 +/- 3113 +/- 3
Thickness, mm
*single wall
All Sizes Finger : 0.14 +/- 0.02
Typical value: 0.13 to 0.15
Palm : 0.10 +/- 0.02
Typical value: 0.10 to 0.11

Physical Properties

Description Standard
Before Aging After Aging
Elongation at Break, % Min 500
Typical value: 500 to 600
Min 400
Typical value: 400 to 500
Tensile Strength, MPa Min 14
Typical value: 14 to 18
Min 14
Typical value: 14 to 18
3.3 Freedom from Holes: The sample size and allowable number of non conforming gloves in the samples shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements.
3.4 Visual Defects: The sample size and allowable number of non conforming gloves in the samples for both major and minor defects shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements.
3.5 Packaging Defects: The Sample size and allowable number of non conforming in the samples for regulatory, visual and critical packaging defects shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements Gloves Counting=100 pcs by count per Dispenser.
3.6 Powder Free Residue:Maximum 2 mg per glove

PRODUCT SPECIFICATION

Nitrile Powder Free Disposable Gloves Finger Textured (short cuff)
SECTION I : PRODUCT DESCRIPTION
1. 1 Type Nitrile Disposable Glove, Powder Free, Online Single Chlorinated, Non sterile
1. 2 Material 100% Synthetic Nitrile Latex
1. 3 Colour Blue
1. 4 Design & Features Ambidextrous, finger textured, beaded cuff
1. 5 Powder No powder lubricant added
1. 6 Storage Condition The gloves shall maintain their properties when stored in a dry condition. Avoid direct sunlight.
1.7 Shelf Life The gloves shall have shelf life of 5 years from the date of manufacture with the above storage condition.
1. 8 Packing Style 100 pcs gloves x 10 dispensers x 1 carton
1. 9 Size Marking The size of gloves shall be marked in the check box on every carton with black ink.
SECTION II: PERFORMANCE REQUIREMENTS | Sampling Plan : ISO 2859 Single Normal
# Characteristics Inspection Level Acceptable Quality Level Reference Standard
2.1 Dimensions S2 4.0 ASTM D6319-19
2.2 Physical Properties S2 4.0 ASTM D6319-19
2.3 Freedom from Holes Air Pump Test GI 1.5 In house practice
2.4
i
ii
Visual Defects:

Major
Visual

Minor Visual

GI 2.5

4.0

In house practice
2.5
i
ii
iii
Packaging Defects:

Regulatory
Visual
Critical incl. Gloves Counting

GI
GI
S2
**

4.0

4.0

In house practice
2.6 Powder Free Residue N=5 N/A ASTM D6319-19

ASTM D6124-06 (2017)

2.7 Mix Size / Mix Glove / Mix Hand Not Allowed

**Unacceptable at any level

SECTION III: PERFORMANCE SPECIFICATION
Dimensions
Description Size Standard
Length, mm All Sizes Min 240
Palm Width, mm XS
S
M
LXL
76 +/- 3

84 +/- 3
94 +/- 3

105 +/- 3

113 +/- 3

Thickness, mm
*single wall
All Sizes Finger : 0.12 +/- 0.02
Typical value: 0.12 to 0.14
Palm : 0.08 +/- 0.02
Typical value: 0.08 to 0.09

Physical Properties

Description Standard
Before Aging After Aging
Elongation at Break, % Min 500

Typical value: 500 to 600

Min 400
Typical value: 400 to 500
Tensile Strength, MPa Min 14

Typical value: 14 to 18

Min 14

Typical value: 14 to 18

3.3 Freedom from Holes: The sample size and allowable number of non conforming gloves in the samples shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements.
3.4 Visual Defects: The sample size and allowable number of non conforming gloves in the samples for both major and minor defects shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements.
3.5 Packaging Defects: The Sample size and allowable number of non conforming in the samples for regulatory, visual and critical packaging defects shall be determined in accordance to Sampling Plan ISO 2859-1 Single Normal using inspection and acceptable quality level as stated in Section II: Performance Requirements, Gloves Counting=100 pcs by count per Dispenser.
3.6 Powder Free Residue:Maximum 2 mg per glove

Your Shopping cart